No.
|
|
|
Product type
|
Standard No.
|
Sample delivery guideline for type test
|
|
1
|
PVC insulated non-sheathed cables and wires
|
1.1
|
60227IEC01(BV)
60227IEC02(RV)
|
GB5023.3
|
Delivery separately for 2 types:
1 pc sample of approaching Min. section area,
1 pc sample of approaching Max. section area.
|
|
1.2
|
60227IEC05(BV)
60227IEC06(RV)
60227IEC07(BV-90)
60227IEC08(RV-90)
|
1 pc sample of random section area for rigid conductor,
1 pc sample of random section area for flexible conductor,
1 pc sample shall be 90 type if involving 90 type products.
|
|
1.3
|
BV
BLV
BVR
|
JB/T8734.2
|
1 pc sample of approaching Max. section area,
1 pc sample of approaching Min. section area,
each 1 pc sample shall be delivered if involving copper, aluminum conductors,
1 pc sample shall be BVR if involving BVR.
|
|
2
|
PVC insulated and PVC sheathed cables
|
2.1
|
60227IEC10(BVV)
|
GB5023.4
|
1 pc sample of approaching Min. section area and most cores,
1 pc sample of approaching Max. section area and least cores.
|
|
2.2
|
BVV
BLVV
BVVB
BLVVB
|
JB/T8734.2
|
1 pc sample of approaching most cores and Min. section area,
1 pc sample of approaching least cores and Max. section area,
each 1 pc sample shall be delivered if involving copper, aluminum conductors,
1 pc sample shall be BVR if involving circular and flat type.
|
|
3
|
PVC insulated flexible cables and wires
|
3.1
|
60227IEC41(RTPVR)
|
GB5023.5
appendix 6
|
1 pc sample of random section area.
|
|
3.2
|
60227IEC42(RVB)
RVB
60227IEC43(SVR)
|
each 1 pc sample of the type required of random section area shall be delivered.
|
|
3.3
|
60227IEC52(RVV)
|
1 pc sample of random specification.
each 1 pc sample shall be delivered if involving circular and flat type.
|
|
3.4
|
60227IEC53(RVV)
RVV
|
1 pc sample of 2 cores flat type,
1 pc sample of most cores and Max. section area,
1 pc sample of 3 cores random section area
|
|
3.5
|
RVS
|
JB/T8734.3
appendix 6
|
1 pc sample of random section area
|
|
4
|
PVC insulated and PVC sheathed lift cables
|
60227IEC71f(TVVB)
TVVB
60227IEC71c(TVV)
|
GB/T5023.6
appendix 7
|
1 pc sample of approaching most cores and Min. section area,
1 pc sample of approaching least cores and Max. section area,
each 1 pc sample shall be delivered if involving segment and circular type.
|
|
5
|
PVC insulated and PVC sheathed oil-resistant flexible cables
|
60227IEC74(RVVYP)
60227IEC75(RVVY)
|
GB5023.7
|
1 pc sample of approaching most cores and Min. section area,
1 pc sample of approaching least cores and Max. section area,
1 pc sample shall be P type if involving P type.
|
|
6
|
PVC insulated wires for internal wiring of equipment and /or screened wires
|
AV
AVR
AVRB
AVRS
AVVR
AV-90
AVR-90
AVP
RVP
RVVP
RVVP1
AVP-90
RVP-90
|
JB/T8734.4
|
Single core wires: 1 pc sample of random section area,
Not less than 2 cores: 1 pc sample approaching most cores,
1 pc sample of various screened type if involving screened type,
1 pc sample of random 90 type if involving 90 type,
1 pc sample of B type if involving B type,
1 pc sample of S type if involving S type.
|
|
7
|
Heat resistant rubber insulated cables
|
6.1
|
60245IEC03(YG)
|
GB5013.3
|
1 pc sample approaching Max. section area
|
|
6.2
|
60245IEC04(YYY)
60245IEC05(YRYY)
60245IEC06(YYY)
60245IEC07(YRYY)
|
GB5013.7
|
1 pc sample approaching Min. section area,
1 pc sample approaching Max. section area,
1 pc sample of second sort of conductor approaching Max. section area if involving flexible conductor.
|
|
8
|
Rubber insulated lift cables and /or arc welding cables
|
7.1
|
60245IEC70(YTB)
60245IEC74(YT)
60245IEC75(YTF)
|
GB5013.5
|
1 pc sample of each type,
at least 1 pc sample approaching most cores
|
|
7.2
|
60245IEC81(YH)
60245IEC82(YHF)
|
GB5013.6
|
1 pc sample approaching Max. section area,
1 pc sample approaching Min. section area of another type if involving 2 types.
|
|
9
|
Rubber insulated extra-flexible cables
|
60245IEC86(RQ)
60245IEC87(RQVJ)
60245IEC88(RQVJVJ)
|
GB/T5013.8
|
1 pc sample of each type, random cores and section areas.
|
|
10
|
Tough rubber sheathed flexible cables and wires for general purposes
|
8.1
|
60245IEC53(YZ)
|
GB5013.4
|
1 pc sample of approaching most cores and Min. section area,
1 pc sample of approaching least cores and Max. section area.
|
|
8.2
|
60245IEC57(YZW)
|
|
1 pc sample of approaching most cores and Min. section area,
1 pc sample of approaching least cores and Max. section area.
|
|
8.3
|
60245IEC66(YCW)
|
|
1 pc sample of approaching most cores and Min. section area,
1 pc sample of approaching least cores and Max. section area.
|
|
8.4
|
60245IEC58(YSF)
60245IEC58f(YSFB)
|
|
1 pc sample of random specification, 1 pc 2 cores circular type sample if involving 2 cores circular type.
|
|
8.5
|
YQ
YQW
YZ
YZW
YZB
YZBW
YC
YCW
|
JB/T8735.2
|
1 pc sample of approaching least cores and Max. section area,
1 pc sample of approaching most cores and Min. section area,
Random specification sample for the third pc if involving general type, flat type and W type and/or involving Q, Z and C types. All types shall cover the sample type.
|
|
11
|
Rubber insulated braided cords
|
60245IEC51(RX)
|
GB5013.4
|
1 pc sample of approaching Max. section area,
1 pc sample of RXH type if involving RXH type.
|
|
RX
RXS
RXH
|
JB/T8735.3
|
|
12
|
Insulated cables(wires) for railway vehicles
|
DCXF series
DCH series
DCEH series
|
GB12528.1
GB12528.11
JB/T8145
|
1 pc sample of approaching Max. section area,
1 pc sample of approaching Min. section area,
at least 1 pc sample of each series,
for WDZ-DCYJ series and 2 sorts of operation temperature125℃, 150℃, samples shall be delivered separately; one shall be thin-wall type if involving thin-wall type, if meet requirements above, for other series, random type and specification samples shall be delivered.
|
|
13
|
Flexible rubber-sheathed coal-cutter cables
|
UC
UCP-0.38/0.66
UCP-0.66/1.44
|
GB12972.2
|
1 pc sample of approaching most cores and Min. section area,
1 pc sample of approaching least cores and Max. section area,
at least 1 pc sample of each shielding type.
|
|
UCPJB
UCPJR
|
GB12972.3
|
|
UCPT
|
GB12972.4
|
|
14
|
Flexible rubber-sheathed cables for mining purposes
|
UY
UYP-0.38/0.66
UYP-0.66/1.44
|
GB12972.5
|
1 pc sample of approaching most cores and Min. section area,
1 pc sample of approaching least cores and Max. section area,
at least 1 pc sample of each shielding type.
|
|
UYPJ
|
GB12972.6
|
|
UYP
UYPT
UYPD
UYPTD
|
GB12972.7
|
|
UYQ
|
GB12972.9
|
|
15
|
Flexible drill cables for mining purposes
|
UZ
UZP
|
GB12972.8
|
1 pc sample of random section area, 1 pc sample of UZPUZP if involving P type.
|
|
16
|
Miner’s cap lamp cords
|
UM
UM-1
|
GB12972.10
|
1 pc sample of random section area, 1 pc sample of UM-1 if involving UM-1 type.
|